EasyManua.ls Logo

Kramer VS-44H2

Kramer VS-44H2
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kramer Electronics Ltd.
VS-44H2 Protocol 3000
48
Function
Description
Syntax
Parameters/Attributes
Example
EDID-
AUDIO
Set audio capabilities
for EDID.
COMMAND
#EDID-AUDIOinput_id,audio_format<CR>
FEEDBACK
~nn@EDID-AUDIOin_index,audio_format<CR><LF>
input_id Number that
indicates the specific input:
1 Input 1
2 Input 2
3 Input 3
4 Input 4
audio_format Audio block
added to EDID:
0 Auto
1 LPCM 2CH
2 LPCM 6CH
3 LPCM 8CH
4 Bitstream
5 HD
Set Input 1 audio capabilities
for EDID to LPCM 6CH:
#EDID-AUDIO1,2<CR>
EDID-
AUDIO?
Get audio capabilities
for EDID.
COMMAND
#EDID-AUDIO?input_id<CR>
FEEDBACK
~nn@EDID-AUDIOinput_id,audio_format<CR><LF>
input_id Number that
indicates the specific input:
1 Input 1
2 Input 2
3 Input 3
4 Input 4
audio_format Audio block
added to EDID:
0 Auto
1 LPCM 2CH
2 LPCM 6CH
3 LPCM 8CH
4 Bitstream
5 HD
Get Input 1 audio capabilities
for EDID:
#EDID-AUDIO?1<CR>
EDID-CS
Set EDID color space.
Set command might
change the current
EDID.
COMMAND
#EDID-CSinput_id,cs_mode<CR>
FEEDBACK
~nn@EDID-CSinput_id,cs_mode<CR><LF>
The following attributes comprise
the ID:
input_id Output number
1 Input 1
2 Input 2
3 Input 3
4 Input 4
cs_mode Color space
0 RGB
4 Auto
Set Input 3 EDID color space
to RGB:
#EDID-CS3,1<CR>
EDID-CS?
Get EDID color space.
Get command might
change the current
EDID.
COMMAND
#EDID-CS?input_id<CR>
FEEDBACK
~nn@EDID-CSinput_id,cs_mode<CR><LF>
The following attributes comprise
the ID:
input_id Output number
1 Input 1
2 Input 2
3 Input 3
4 Input 4
cs_mode Color space
0 RGB
4 Auto
Get Input 2 EDID color
space:
#EDID-CS?3<CR>
EDID-DC
Force removal of deep
color on EDID or
leaving it as in the
original EDID.
COMMAND
#EDID-DCin_index,deep_color_state<CR>
FEEDBACK
Get:
~nn@EDID-DCin_index,deep_color_state<CR><LF>
in_index Number that
indicates the specific input:
1 Input 1
2 Input 2
3 Input 3
4 Input 4
deep_color_state
0 Don’t change
1 Remove deep color
Remove deep color on input
2:
#EDID-DC2,1<CR>
EDID-DC?
Get the input's deep
color removal status.
COMMAND
#EDID-DC?in_index<CR>
FEEDBACK
Get:
~nn@EDID-DCin_index,deep_color_state<CR><LF>
in_index Number that indicates
the specific input:
1 Input 1
2 Input 2
3 Input 3
4 Input 4
deep_color_state
0 Don’t change
1 Remove deep color
Get Input 3 deep color
removal status:
#EDID-DC3,1<CR>
ETH-PORT
Set Ethernet port
protocol.
If the port number
you enter is already in
use, an error is
returned.
The port number must
be within the following
range: 0-(2^16-1).
COMMAND
#ETH-PORTport_type,port_id<CR>
FEEDBACK
~nn@ETH-PORTport_type,port_id<CR><LF>
port_type TCP/UDP
TCP
UDP
port_id TCP/UDP port number
(0 65535)
Set the Ethernet port
protocol for TCP to port
12457:
#ETH-PORT0,12457<CR>
ETH-PORT?
Get Ethernet port
protocol.
COMMAND
#ETH-PORT?port_type<CR>
FEEDBACK
~nn@ETH-PORTport_type,port_id<CR><LF>
port_type TCP/UDP
TCP
UDP
port_id TCP / UDP port number
(0 65535)
Get the Ethernet port
protocol for UDP:
#ETH-PORT?1<CR>
FACTORY
Reset device to factory
default configuration.
This command
deletes all user data
from the device. The
deletion can take some
time.
Your device may
require powering off
and powering on for the
changes to take effect.
COMMAND
#FACTORY<CR>
FEEDBACK
~nn@FACTORYok<CR><LF>
Reset the device to factory
default configuration:
#FACTORY<CR>

Other manuals for Kramer VS-44H2