VS-62HA - Configuring and Maintaining the VS-62HA
25
8.2 Resetting the VS-62HA to Factory Default Settings
To reset the device to factory default settings:
1. Power off the device.
2. Press and hold down the Reset button on the rear panel.
3. While holding down the Reset button, power on the device.
4. Wait a few seconds and release the button.
The device is reset to its factory settings.
Note: When running a factory reset from Protocol 3000, you must send the
two commands: #FACTORY<CR> and #RESET<CR>.
8.3 Upgrading the Firmware
The VS-62HA can be upgraded via any of the following:
Mini USB
RS-232
Ethernet
For instructions on upgrading the firmware see “K-Upload Software”.