60
VS-62HA - Protocol 3000 Commands
Command - PRIO
Command Type - System
Command Name
Permission
Transparency
Set:
PRIO
Administrator
Public
Get
PRIO?
Administrator
Public
Description
Syntax
Set:
Set input priority
#PRIOinput_id,prio
Get:
Get input priority
#PRIO?input_id
Response
~ nn@PRIOinput_id,prio␍␊
Parameters
input_id - window number setting new source
prio - assigned priority (1.. max priority)
Response Triggers
After execution, response is sent to the com port from which the Set/Get was received
After execution, response is sent to all com ports if PRIO was set by any other external control device
(button press, device menu and similar)
Notes
The PRIO max value may vary for different devices
Command - SIGNAL
Command Type - System
Command Name
Permission
Transparency
Set:
-
-
-
Get
SIGNAL?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get input signal lock status
#SIGNAL?inp_id
Response
~ nn@SIGNAL inp_id,status ␍␊
Parameters
inp_id - input number
status - lock status according to signal validation (see Section 18.18 Signal Validation)
Response Triggers
After execution, a response is sent to the com port from which the Get was received
Response is sent after every change in input signal status ON to OFF, or OFF to ON
Notes

Table of Contents