7 Servicing/Maintenance
47 of 96
Sewatec
Closing the inspection hole
Fit new O-ring 412.05.
Fit inspection cover 164.02.
Fit discs 550.04 and nuts 920.17 on screws 900.02. Tighten the nuts.
Observe the instructions on commissioning/start-up. (ðSection6.1.1,Page39)
7.2.3 Lubrication and lubricant change
DANGER
Excessive temperatures as a result of bearings running hot or defective bearing
seals
Explosion hazard!
Fire hazard!
Damage to the pump set!
Regularly check the condition of the lubricant.
7.2.3.1 Changing the grease
Lubricating nipples at the bearing bracket allow re-lubrication of the rolling element
bearings without opening the pump.
DANGER
Dry running
Explosion hazard!
Re-lubricate explosion-proof pump sets outside potentially explosive
atmospheres.
WARNING
Hands or foreign objects in the pump casing
Risk of injuries, damage to the pump!
Check that the inside of the pump is free from any foreign objects. Remove any
foreign objects.
Never insert your hands or any other objects into the pump, if the pump set has
not been disconnected from the power supply and secured against
unintentional start-up.
CAUTION
Incomplete re-lubrication
Bearing damage!
Always re-lubricate the bearings with the pump set in operation.
NOTE
Prior to the first re-lubrication, fill the cavities of the bearing bracket in the area to
be re-lubricated with grease.
ü The pump set remains installed in the piping.
1. Press the grease through lubricating nipples 636.02 / 636.03.