Alarm messages
Control box
Quantron S
59
8
Only on machine with 2 low level sensors
• Left hopper empty
9 Blower speed too high
• The blower exceeds the maximum
authorized speed value.
The alarm disappears automatically if the
speed decreases below the maximum
authorized speed value.
1
0
Blower speed too low
• The blower does not reach the minimum
authorized speed value.
The alarm automatically disappears when the
speed exceeds the minimum authorized
speed value.
Alarm only possible on machines driven by an
electric or hydraulic motor:
• The pre-metering is activated by pressing
the start/stop key but the blower has not
reached the minimum authorized speed
value.
1
1
Pre-metering stopped
Alarm only possible on machines driven by an
electric or hydraulic motor:
• The pre-metering is stopped and there
was no forward signal sent before 5
seconds.
1
2
Data transfer error
No RS232 connection
• A fault has occured during the data
transfer towards/as from the control box
1
3
Desired weight outside limits
• The maximum and minimum alarm values
depend on the seed variety.
1
4
Forward speed or metering volume too high
max. 20 km/h
• The speed value is hoo high for calibration
test.
1
5
Calibration flap not closed
• The flap is still in calibration test position
and the blower is rotating.
1
6
Memory full
Deletion of a private table
• The maximum number of 46 seed
adjustment charts has been reached.
Nr. Error messages
Description
• Possible causes