Control box
58
Quantron S
Alarm messages
$Alarm messages
When an anomaly is detected, an alarm screen is
displayed and a permanent buzzer sounds.
1. Alarm signification
Nr. Error messages
Description
Possible causes
1 Fault in metering unit!
The metering unit does not rotate
although the machine is lowered.
2
Maximum application rate reached!!
Forward speed or metering volume too high
Alarm only possible on machines driven by an
electric or hydraulic motor
The maximum motor speed has been
reached.
3
Minimum application rate reached!
Forward speed or metering volume too low
Alarm only possible on machines driven by an
electric or hydraulic motor
Forward speed or metering volume too
low.
4 Volume outside limits
The quantity collected does not reach or
exceeds by 20 % the theoretical value to
collect.
5
Only on machine with a low level sensor
Hopper empty
6
Only on machine with 2 low level sensors
Right hopper empty
7
Data is deleted!
Delete = START
Abort = ESC
Alarm message for preventing inadvertent
deleting of all data