Functioning during work
Control box
Quantron S
43
$Functioning during work
1. Distribution stop/start
- Lower the marker and the coulter bar.
Sowing start
- Start metering unit in the following situations:
• Sowing start
• Power on.
- Press on the button Start/Stop.
The metering unit will run for 6 seconds in a premetering
function.
If the tractor starts to move forward during these
6 seconds, the machine will automatically switch into
work application rate.
If the tractor moves forward at a speed of less than
1,5 km/h, the application rate is stopped.
Impulse mode
In automatic mode, the metering unit automatically stops
when lifting and starts when lowering the drill.
The metering function on the headlands is controlled by
the working position sensor (ABS).
The metering unit only starts if following
conditions are met:
- The machine is in working position
- The blower rotates
- The calibration flap is closed.
- The low level sensor indicates the
presence of seed inside the hopper.
- The minimum blower speed is exceeded
(1,5 km/h).