EasyManua.ls Logo

KUHN Quantron S - Page 46

KUHN Quantron S
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control box
44
Quantron S
Functioning during work
Drilling in field corners
To maintain the seed quality in the corners, use the
premetering function.
- Press 2 times Start/Stop key.
The metering unit will run for 6 seconds in a premetering
function.
Move forward with the tractor while premetering is
running.
Momentary drilling stop
- Press button Start/Stop in the following situations:
At the end of work
Filling the hopper.
Using the manual mode
In the manual mode (MAN km/h), the premetering is
impossible. The programmed speed is the reference
speed.
- Press on the button Start/Stop.
Press Start/Stop button when seeding should
start again.
Respect the reference speed during work.
Otherwise over and underdosing will occur.