Fig. 8-2: Maintenance chart, KR IONTEC standard and Foundry var-
iants
Maintenance table, KR IONTEC standard variants
Interval Item Activity Auxiliary substances and
consumables
Once only, af-
ter
100 h
1 Check the tightening torque for an-
chor nuts and holding-down bolts.
-
5,000 h - Carry out a visual inspection of visible
flexible tubes and check for damage.
In the case of damage and/or cracks,
have the cable set exchanged by KU-
KA Service.
-
20,000 h 2 Grease cable set A1
(>>> 8.2 "Greasing cable set A1"
Page 195)
Lubricating grease Optitemp
RB2
0.03 kg
20,000 h
or 5 years
at the latest
3 Perform oil change on
gear unit A6.
(>>> 8.8 "Oil change in A6"
Page 213)
Optigear ALR 320
Initial filling quantity: 0.24 l
20,000 h
or 5 years
at the latest
4 Perform oil change on
gear unit A5.
(>>> 8.7 "Oil change in A5"
Page 210)
Optigear ALR 320
Initial filling quantity: 0.60 l