Fig. 9-52: KR 20 R3100 Removing/installing motors A4 and A5
1 M5x14-8.8-A2K Allen screw (4x per motor)
2 Motor A4
3 Motor A5
4 Sinuous spring 0.25x11.43x15.88 (2x)
5 Connecting shaft R3100 (2x)
6 Arm extension
7 M6x35-8.8-A2K Allen screw with conical spring washer (18x)
9. Clean the surface between the in-line wrist with arm extension and the
arm and apply a thin but continuous coat of Drei Bond 5204 HV adhe-
sive.
10. Attach the in-line wrist with arm extension to the arm using 18
M6x35-8.8 A2K Allen screws and tighten the screws with a torque
wrench in diagonally opposite sequence. Increase the tightening tor-
que to the specified value in several stages.
11. Fasten the motor cable to the first holder at the marked position with a
cable strap.
12. Plug the plug connection A6 back together and fasten the holder (far
right position) using a cable strap.
13. Fasten both holders with 2 M6x12-8.8-A2K Allen screws each.
9.5.4.7 Mounting the cover
Procedure
1. Place the cover on the robot arm and fasten in place using 14
M6x16-8.8-A2K Allen screws. Tighten the screws in diagonally oppo-
site sequence.
KR IONTEC
294/344 | www.kuka.com MA KR IONTEC V4 | Issued: 11.05.2021