Visual inspection, check for leaks.
Run the program in T1 mode and look out for irregularities.
8.7 Oil change in A5
Description
The following sections describe the A5 gear oil change for floor-mounted
robots. For ceiling-mounted robots, the procedure is to be applied analo-
gously, but with the drain and filler holes reversed.
Equipment
The following equipment is required:
Designation Article number
Set of Allen keys
1.5; 2; 2.5; 3; 4; 5; 6; 8; 10 mm
-
Torque wrench
min. 2 Nm to 30 Nm
-
Socket wrench set -
Collection receptacle -
KUKA oil pump 0000-180-812
Material
The following material is required:
Designation Article number Quantity
Optigear ALR 320
KR 30 R2100
KR 50 R2100
KR 50 R2500
KR 50 R2500 F
KR 70 R2100
KR 70 R2100 F
(>>> 12.2 "Aux-
iliary and oper-
ating materials
used"
Page 336)
Initial fill-
ing quan-
tity:0.60 l
Tightening torques
The tightening torques can be found under: (>>> 12.1 "Tightening
torques" Page 335)
These are valid for screws and nuts where no other specifications are giv-
en.
Screws of strength class 10.9 and higher as well as screws with test cer-
tification may only be tightened once with the rated tightening torque.
When the screws are first slackened they must be replaced with new
ones.
Precondition
The gear unit is at operating temperature.
The arm and in-line wrist are in horizontal position.
KR IONTEC
210/344 | www.kuka.com MA KR IONTEC V4 | Issued: 11.05.2021