Fig. 11-10: Installing PURGE option C
1 Compressed air supply connection
2 M6x16 hexagon bolt (2x)
3 Bracket
4 M4x10 Allen screw with washer (2x)
5 Service unit, air
6 M4x6 Allen screw (2x)
7 Plate
8 Pressure regulator
9 Holder for pressure regulator
M4x6 Allen screw (2x)
10 Robot connection with plastic hose
11.4.1.2 Concluding work
The following concluding work must be carried out:
Carry out a test run in T1 mode and look out for irregularities.
KR IONTEC
330/344 | www.kuka.com MA KR IONTEC V4 | Issued: 11.05.2021