1-3-2
3JG
Section
Item
Maintenance item contents
Initial
No. setting*
U600 Initializing all data —
U601 Initializing permanent data —
U603 Setting user data 1 —
U604 Setting user data 2 —
U605 Clearing data —
U610 Setting system 1
• Setting the number of lines to be ignored
when receiving a fax at 100% magnification 3
• Setting the number of lines to be ignored
when receiving a fax in the auto reduction mode 3
• Setting the number of lines to be ignored
when receiving a fax (A4R, 8 1/2 x 11) in the auto reduction mode 3
U611 Setting system 2
• Setting the number of adjustment lines for automatic reduction 7
• Setting the number of adjustment lines for automatic reduction
when A4 paper is set 22
• Setting the number of adjustment lines for automatic reduction
when letter size paper is set 26
U612 Setting system 3
• Selecting if auto reduction in the auxiliary direction is to be performed —
• Setting the automatic printing of the protocol list —
U620 Setting the communication system —
U625 Setting the trasmission system
• Setting the auto redialing interval —
• Setting the number of times of auto redialing —
U630 Setting communication control 1
• Setting the communication starting speed —
• Setting the reception speed —
• Setting the waiting period to prevent echo problems at the sender —
• Setting the waiting period to prevent echo problems at the receiver —
U631 Setting communication control 2
• Setting ECM transmission —
• Setting ECM reception —
• Setting the frequency of the CED signal —
U632 Setting communication control 3
• Setting the DIS signal to 4 bytes —
• Setting the short protocol transmission —
• Setting the reception of a short protocol transmission —
• Setting the CNG detection times in the fax/telephone auto select mode —
U633 Setting communication control 4
• Enabling/disabling V.34 communication —
• Setting the V.34 symbol speed (3429 Hz) —
• Setting the number of times of DIS signal reception —
• Setting the reference for RTN signal output —
U634 Setting communication control 5
U640 Setting communication time 1
• Setting the one-shot detection time for remote switching —
• Setting the continuous detection time for remote switching —
U641 Setting communication time
• Setting the T0 time-out time —
• Setting the T1 time-out time —
• Setting the T2 time-out time 69
• Setting the Ta time-out time 30
• Setting the Tb1 time-out time 20
• Setting the Tb2 time-out time 80
• Setting the Tc time-out time 60
• Setting the Td time-out time —
(2) Maintenance mode item list