Maintenance
Description
item No.
3JG
1-3-16
U640 Setting communication time 1
Description
Sets the detection time when one-shot detection is selected for remote switching. (This setting item will be
displayed, but the setting made is ineffective.)
Sets the detection time when continuous detection is selected for remote switching. (This setting item will be
displayed, but the setting made is ineffective.)
Method
1. Press the enter key.
2. Select the item to be set using the up/down cursor keys.
Display Description Setting range
1:TIME (ONE) Sets the one-shot detection time for remote switching. 0 to 255
2:TIME (CON) Sets the continuous detection time for remote switching. 0 to 255
3. Change the setting using the left/right cursor keys.
4. Press the enter key. The value is set.
Completion
Press the back key. The screen for selecting a maintenance item No. is displayed.
Completion
Press the back key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.
U634 Setting communication control 5
Description
Sets the maximum number of error bytes judged acceptable when receiving a TCF signal. Used as a measure
to ease transmission conditions if transmission errors occur.
Method
1. Press the enter key.
2. Change the setting using the left/right cursor keys.
Description Setting range
Number of allowed error bytes when detecting TCF 0 to 255
3. Press the enter key. The value is set.
Completion
Press the back key. The screen for selecting a maintenance item No. is displayed.
U633