Oxygen saturation
Only for SimNewB™ Advanced version:
A standard SPO
2
probe can be attached to the SimNewB to
simulate SPO
2
readings to the provided monitor.
Note: There is no interface between the SPO
2
probe and the
SimNewB system.
It is up to the instructor to set the SPO
2
value that shall be vi-
sible to the simulation team members on the provided moni-
tor.
5. Circulation
Heart rate and Pulse
The SimNewB manikin has a heartbeat and palpatable umbilical
and right brachial pulses. The palpatable pulses can be switched
on or off by the instructor. The heartbeat can be listened to
using a stethoscope at the left side of the chest. The heart rate
can be varied between 0 and 300 bpm.
Even if the Remote Control sets the pulse to off, palpating the
brachial pulse will turn on all pulses unless the BP cuff is inflated
to 10 mmHg or more.