FLAPS_V6_HBR_datasheet_manual_EN.odt
3.3 Allowed operating conditions
Parameter Value Unit Notes
Operating temperature -30 ÷ +75 °C
Operating humidity 10 ÷ 90 %RH
non-condensing
Operating atmospheric pressure 800 ÷ 1100 hPa
IP protection IP20 -
NOTE The above specifications apply to the control unit.
3.4 Lifetime and warranty
The product is designed with regard to its intended use, for a long service life, higher than
the intended service life (see below).
However manufacturer LAMBERT ELECTRONIC s.r.o. HIGHLY RECOMMENDS to
replace the product with a new one when it reaches its planned service life
(any of the parameters below), or at the latest 10 years after purchase.
Parameter Lifetime Notes
Device flight hours 5000 h
Motor engine hours 500 h motor overload reduces service life to 20%
Rotary switch cycles 30000 turns
Position sensor cycles 15000 passing the sensor path in one direction
Note: The above parameters are valid when the prescribed operating parameters (supply voltage, operating
temperature, etc.) are observed. These parameters are recorded in the device and evaluated in the event of
the warranty complaint.
The manufacturer grants a 24-month warranty from the date of purchase. Exceeding
any of the above durability parameters will void the warranty if this occurs before the
warranty period has elapsed since the product was purchased.
The warranty also void in case of using the product in violation of this manual!
12/33