5.5 Position programming mode
This mode is used to precisely set (or fine-tune pre-programmed) positions to which the
actuator or the flaps connected to it are adjusted (extended and retracted).
The control unit has factory preset target positions, with target position 0 corresponding
to the fully retracted actuator.
NOTE: Position of each target position (0,1,2,optionally 3 for the HBR variant) is
programmed INDIVIDUALLY.
ATTENTION! All malfunctions cancel or prevent the Position programming mode, except
for the Programmed Positions Error, which disappears only after all positions have been
programmed correctly (and therefore it must not block Position programming mode) .
To program one particular position, the following procedure must be performed:
Set the rotary switch to the position intended for programming
Press and hold both SET buttons until the LED of the corresponding
programmed position flashes orange quickly (flashing at approx. 5x/s)
release SET buttons (programming mode is now active)
Press one of the SET buttons to move the actuator rod to the desired position
the piston rod is only moved when the button is pressed, the actuator stops
when the button is released
If You are programming the positition on the very limit of mechanical
range of piston rod (i.e. at one of the stops with limit switch activated), DO
NOT release the SET button used to reach this position, but hold in until
position correspondin LED starts quickly alternating orange/green colors (5x/s).
This comes approximately 3 seconds after actuator reaches limit switch and
stops movement.
This acts as a confirmation given to the control unit that reaching limit switch
is being intended
If You do not follow this, automatic control adjustment may not reach fully
the intended position (while limit switch activated)
release SET button
Quickly press and HOLD both SET buttons
The corresponding LED changes the flashing to slow alternation of colors orange
and green, both colors alternate approx. 1x/s (signalizing running of calculations
and storig the data into device’s memory)
approx after 2 seconds LED turns off
After LED turns off, release SET buttons (exits Position programming mode)