FLAPS_V6_HBR_datasheet_manual_EN.odt
5.2 Errors and faults
The device is able to detect various types of errors and faults. These errors and faults are
indicated by LEDs and in most cases functionality of the normal (automatic) mode is
blocked.
In particular, the following faults are an exception:
• Fault Motor overcurrent
◦ when the rotary switch is turned, the fault is cleared and the device waits for
the next command
◦ if this fault continues to occur, it is likely that the engine, wiring, or airplane
mechanics are defective; turn the device off and do not use it
◦ power reset also clears this error
• Position sensor malfunction
◦ after indication of this fault and then turning the rotary switch to one of the
positions 1 or 2, the safety (manual) mode will be activated, which is described
in more detail in the relevant chapter of this manual
◦ if this error is corrected / fade away, error indication is automatically erased and
the device returns to normal (automatic) mode
• Move to position timeout error
◦ after turning the rotary switch, the fault is cleared and the device automatically
returns to normal (automatic) mode and immediately starts to move the flaps to
the position corresponding to the current setting of the rotary switch
◦ power reset also clears this error
Other faults, with some exceptions, remain valid until their cause has subsided.
A detailed list of errors and faults, their causes, indications, remedies, etc., is found in the
last chapter of this document.
ATTENTION! If the device is permanently in a malfunction which cannot be corrected,
turn off the device and do not use it. Then check the mechanical installation, wiring, etc.
22/33