EasyManua.ls Logo

Lantronix EDS4100

Lantronix EDS4100
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4: Configuration Using the Web Manager
EDS4100 4 Port Device Server User Guide 50
Table 4-6. Tunnel – Start/Stop Chars Page
Tunnel –
Start/Stop Chars
Page Settings
Description
Start Character Enter the start character. When this character is read on the
serial line, it either initiates a new connection (for a tunnel in
Connect mode) or enables a tunnel in Accept mode to start
listening for connections. Default is <none>.
Stop Character Enter the stop character. When this character is read on the
serial line, it disconnects an active tunnel connection. Default is
<none>.
Echo Start
Character
Select whether the start character is forwarded (or “echoed’)
through the selected tunnel when the serial line is read. Choices
are:
On = echo the start character on the selected tunnel when the
serial line is read.
Off = do not echo the start character. (default)
Echo Stop
Character
Select whether the stop character is echoed through the
selected tunnel when the serial line is read. Choices are:
On = echo the stop character on the selected tunnel when the
serial line is read.
Off = do not echo the stop character. (default)

Table of Contents

Other manuals for Lantronix EDS4100

Related product manuals