Table 4-6. Tunnel – Start/Stop Chars Page
Tunnel –
Start/Stop Chars
Page Settings
Description
Start Character Enter the start character. When this character is read on the
serial line, it either initiates a new connection (for a tunnel in
Connect mode) or enables a tunnel in Accept mode to start
listening for connections. Default is <none>.
Stop Character Enter the stop character. When this character is read on the
serial line, it disconnects an active tunnel connection. Default is
<none>.
Echo Start
Character
Select whether the start character is forwarded (or “echoed’)
through the selected tunnel when the serial line is read. Choices
are:
On = echo the start character on the selected tunnel when the
serial line is read.
Off = do not echo the start character. (default)
Echo Stop
Character
Select whether the stop character is echoed through the
selected tunnel when the serial line is read. Choices are:
On = echo the stop character on the selected tunnel when the
serial line is read.
Off = do not echo the stop character. (default)

Table of Contents

Other manuals for Lantronix EDS4100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EDS4100 and is the answer not in the manual?

Lantronix EDS4100 Specifications

General IconGeneral
BrandLantronix
ModelEDS4100
CategoryServer
LanguageEnglish

Related product manuals