EasyManua.ls Logo

LELY DISCOVERY 90 S - Test a Route; Make Sure the Battery Is Charged; Make Sure the Battery Is Charging

LELY DISCOVERY 90 S
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.4002.8501.0 B
7-4 Test and Adjustment
2. Select the noted route number and push
.
3. Make a note of the fault categories (A-E) that have an (action) number and note the numbers (see
Failure Analysis on page 4-20).
4. Push
and make a note of the fault categories (F-H) that have an (action) number and note the
numbers.
5. Make a note of the percentage bump points.
6. Make a note of the percentage short routes.
7. Push
and look up the explanation of the noted fault categories (A-H).
8. Make sure you understand the explanation of the noted fault categories.
9. Make a test route and find out where the notes risky action numbers appear (see Test a Route on
page 7-4).
10. Delete the route (see Delete a Route on page 5-29).
11. Make a new route.
7.3.2 Test a Route
1. Put the route into a manual route.
2. Start the manual route (see Start, Stop or Pause a Manual Route on page 5-33).
3. Find the actions and action numbers on the display of the user interface of the Lely Control app.
4. Make sure the route is correct.
7.3.3 Make sure the Battery is Charged
1. Stop the time path to take the machine out of operation (see Start or Stop the Time Path on
page 5-33).
2. In the main menu of the Lely Control app, select Work and push
.
Figure 47. Battery voltage
3. Make sure the battery voltage is more than
12500 mV (see figure 47 on page 7-4).
4. If the voltage is less then 12500 mV:
1. Drive the Machine to the Charging Station
(see page 5-7).
2. Make sure the Battery is Charging (see page
7-4).
5. Charge the battery for one hour.
7.3.4 Make sure the Battery is Charging
1. Make sure the machine is connected to the charging station.
in n o vato rs in ag ricu ltu r e