5.4006.8501.0 B
Troubleshooting 8-1
8 Troubleshooting
8.1 Introduction
This chapter contains the troubleshooting procedures for the machine.
• Alarms and reports.
• Troubleshooting table.
• Recovery procedures.
8.2 Alarms and reports
The machine monitors itself continuously. As soon as it detects an error it generates a message, the
system also generates and displays reports with important information:
• A critical alarm message: 3 beeps sound and the machine stops functioning. The user interface on the
smartphone displays the message ALARM with a description. The error requires an error recovery
procedure.
• A non-critical report is recorded in the report list, the machine continues functioning (see Report List
on page 8-11).
• The system also displays information about the operation of the machine (see Information Report List
on page 8-13).
8.2.1 Recover Alarms
When the machine is in normal operation and a critical alarm occurs:
• The machine stops.
• An alarm message is displayed on the smartphone.
• The LED in the pause button on the machine blinks.
• An alarm sounds.
To recover the critical alarm:
1. Push any key on the smartphone to accept the alarm. The alarm sound stops. The LED in the pause
button still blinks.
2. Remove the cause of the alarm (see Alarm List on page 8-3).
3. Start the time path to put the machine into operation (see Time Path ON/OFF on page 4-12)
8.2.2 Read Alarm Messages
1. Start the Lely Control Application (see page 5-4).
2. Stop the time path to take the machine out of operation (see Start or Stop the Time Path on page 5-
32).
3. In the main menu of the Lely Control app, select Alarms and push
.
in n o vato rs in ag ricu ltu r e