7 Maintenance, Troubleshooting Lenord+Bauer
66 GEL 2444
English
Troubleshooting
Malfunction Possible causes Remedy
No output signal or
erroneous output
signal
Electrical connection faulty
Check all electrical connections
between MiniCODER and power
supply, as well as the evaluation
electronics for correctness and
secure contact, and ensure they
are dry.
Incorrect air gap between
measuring surface and tar-
get wheel
Check whether the required val-
ue is maintained in all (climatic)
conditions over a complete tooth
wheel revolution.
Using a torque wrench, check
whether the screws are correctly
tightened.
Measuring surface of target
wheel damaged
Replace the damaged compo-
nent.
Determine the cause of the dam-
age and rectify it.
Counting direction
incorrect
Track assignment incorrect
Check the connections for the
track signals and change them
if necessary (direction of rotation
assignment: page 55)