Lenord+Bauer 7 Maintenance, Troubleshooting
GEL 2444 65
English
7 Maintenance, Troubleshooting
WARNING
Magnetic field!
Ensure that there is at least 30 cm spacing between the implants
and the products.
CAUTION
Magnetic field!
Hold the MiniCODER in such a way as to avoid crushing of fingers
or skin.
NOTICE
Electrostatic discharge!
Only touch the connector pins and connection wires if your body is
suitably earthed.
The MiniCODER does not contain any moving parts and is therefore largely mainte-
nance-free.
Maintenance
When? What?
MiniCODER faulty Replace the MiniCODER.
Regularly Check the MiniCODER for damage.
Make sure there are no foreign bodies in the installation space
for the MiniCODER.
Contamination!
Do not use a high pressure cleaner.
Clean the MiniCODER with a damp cloth. Use only
water or a non-corrosive cleaning agent.