If the system-level
diagnostics tests…
Then…
Resulted in some test failures Determine the cause of the problem.
a.
Exit Maintenance mode by entering the following
command:
halt
b.
Perform a clean shutdown and disconnect the power
supplies.
c.
Verify that you have observed all the considerations
identified for running system-level diagnostics, that cables
are securely connected, and that hardware components
are properly installed in the storage system.
d.
Reconnect the power supplies and power on the storage
system.
e.
Repeat Steps 1 through 5 of Running device failure
diagnostics.
Resulted in the same test
failures
Technical support might recommend modifying the default
settings on some of the tests to help identify the problem.
a.
Modify the selection state of a specific device or type of
device on your storage system by entering the following
command:
sldiag device modify [-dev
devtype|mb|slot_slotnum_] [-name device] [-selection
enable|disable|default|only]
-selection enable|disable|default|only allows you to
enable, disable, accept the default selection of a specified
device type or named device, or only enable the specified
device or named device by disabling all others first.
b.
Verify that the tests were modified by entering the
following command:
sldiag option show
c.
Repeat Steps 3 through 5 of Running device failure
diagnostics.
d.
After you identify and resolve the problem, reset the tests
to their default states by repeating substeps 1 and 2.
e.
Repeat Steps 1 through 5 of Running device failure
diagnostics.
121