Loading...
If the system-level
diagnostics tests…
Then…
Were completed without any
failures
There are no hardware problems and your storage system
returns to the prompt.
a.
Clear the status logs by entering the following command:
sldiag device clearstatus [-dev
devtype|mb|slot_slotnum_]
b.
Verify that the log is cleared by entering the following
command:
sldiag device status [-dev
devtype|mb|slot_slotnum_]
The following default response is displayed:
SLDIAG: No log messages are present.
c.
Exit Maintenance mode by entering the following
command:
halt
d.
Enter the following command at the Loader prompt to boot
the storage system:
boot_ontap You have completed
system-level diagnostics.
If the failures persist after repeating the steps, you need to replace the hardware.