Configuration
Code table
8
8.5
8.5−10
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0091
Mot cos phi à 0.50 {0.01 } 1.00 Motor cos j
à depending on C0086
l Motor selection in C0086 sets
the corresponding motor
cos j in C0091
l Change of C0091 sets
C0086 = 0
6.6−1
C0092
Mot Ls à 0.00 {0.01 mH} 6553.50 Motor stator inductance
à Value is determined by motor
parameter identification
from C0088, C0089, C0090
and C0091
à Motor selection in C0086 sets
corresponding stator
inductance value in C0092
6.6−1
C0093 Drive ident
Controller identification
l Read only
0 Invalid Defective power section
1 None No power section
14
...
20
9335VC 400V
...
9383VC 400V
Display of the controller used
21
...
28
9334VC 500V
...
9383VC 500V
9321
...
9333
9321 VC
...
9333VC
C0094 Password 0 0 {1} 9999 Password
l C0094 = 1 ... 9999: Free
access to the user menu only
7.2−9
C0095
Mot Io à 0.0 {0.1 A} 1000.0 Motor magnetising current
à dependent on C0086, C0088
and C0091
l Change of C0086 sets C0095
to the Lenze setting
l Change of C0095 sets
C0086 = 0
6.6−1
C0096
0 no protection No password
protection
Parameter access protection
l Extension of the access
protection for AIF bus
systems and CAN with
activated password in C0094
l All codes in the user menu
can continued to be accessed.
1 R protection Read protection
2 W protection Write protection
3 R/W protection Read/write
protection
1 AIF protect. 0 Parameter access protection AIF
2 CAN protect. 0 Parameter access protection
CAN
C0099 S/W version
x.y
Software version
l Read only
x
y
Main version
Subversion