Configuration
Code table
8
8.5
8.5−11
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0101 0.00 {0.01 s} 999.90
Additional acceleration times for
speed setpoint conditioning,
function block NSET
l Additional acceleration and
deceleration times for the
main setpoint
l Activation via binary coding
of digital input signals in
C0788/1 ... C0788/4
l For coding see description of
function block NSET
See System
Manual
(extension)
1 add Tir 0.00
2 add Tir 0.00
... ... ...
15 add Tir 0.00
C0103 0.00 {0.01 s} 999.90
Additional deceleration times
for speed setpoint conditioning,
function block NSET
l Additional acceleration and
deceleration times for the
main setpoint
l Activation via binary coding
of digital input signals in
C0788/1 ... C0788/4
l For coding see description of
function block NSET
1 add Tif 0.00
2 add Tif 0.00
... ... ...
15 add Tif 0.00
C0104
select accel. 0
Selection of acceleration
function of the linear ramp
function generator of NSET
See System
Manual
(extension)
0 a = const Constant acceleration
1 t = const Constant time
2 s = const Constant path
C0105 QSP Tif 5.00 0.00 {0.01 s} 999.90 Quick stop deceleration time
l The deceleration time refers
to a speed variation of
C0011 ... 0
8.2−25
8.2−40
C0107 holding time 0.00 0.00 {0.01 s} 9999.90 Hold time for automatic DC
injection braking (Auto−GSB)
8.2−25
8.2−40
C0108 −199.99 {0.01 %} 199.99 Free control code FCODE108/1
and FCODE108/2
6.5−6
See System
Manual
(extension)
1 FCODE (gain) 100.00 Gain of analog output signal
AOUT1 (X6/62)
l 100 % = gain 1
2 FCODE (gain) 100.00 Gain of analog output signal
AOUT2 (X6/63)
l 100 % = gain 1
C0109 −199.99 {0.01 %} 199.99 Free control code FCODE109/1
and FCODE109/2
1 FCODE (offset) 0.00 Offset of analog output signal
AOUT1 (X6/62)
2 FCODE (offset) 0.00 Offset of analog output signal
AOUT2 (X6/63)
C0114
0 High active HIGH level is active
Inversion of digital input signals
at X5, function block DIGIN
6.5−1
See System
Manual
(extension)
1 LOW active LOW level is active
1 DIGIN1 pol 0 Terminal X5/E1
2 DIGIN2 pol 0 Terminal X5/E2
3 DIGIN3 pol 0 Terminal X5/E3
4 DIGIN4 pol 1 Terminal X5/E4
5 DIGIN5 pol 0 Terminal X5/E5
5 DIGIN6 (ST)
pol
0 Terminal X5/ST