Configuration
Code table
8
8.5
8.5−12
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0116
Selection list 2
Configuration of free digital
outputs (FDO)
l Signals can only be evaluated
when being networked with
automation interfaced
See System
Manual
(extension)
1 CFG: FDO−0 1000 FIXED0
... ... ... ...
32 CFG: FDO−31 1000 FIXED0
C0117
Selection list 2 Configuration of digital inputs
signals, function block DIGOUT
A change of the basic
configuration in C0005 changes
the signal assignment!
6.5−3
See System
Manual
(extension)
1 CFG: DIGOUT1 15000 DCTRL−TRIP Terminal X5/A1
2 CFG: DIGOUT2 10650 CMP1−OUT Terminal X5/A2
3 CFG: DIGOUT3 500 DCTRL−RDY Terminal X5/A3
4 CFG: DIGOUT4 5003 MCTRL−MMAX Terminal X5/A4
C0118
0 High active HIGH level is active
Inversion of digital output
signals, function block DIGOUT
1 LOW active LOW level is active
1 DIGOUT1 pol 1 Terminal X5/A1
2 DIGOUT2 pol 1 Terminal X5/A2
3 DIGOUT3 pol 0 Terminal X5/A3
4 DIGOUT4 pol 0 Terminal X5/A4
C0121 OH7 limit 150 45 {1 °C} 150 Setting of the operating
temperature for monitoring
OH7
l Only for KTY at X8
l Monitoring OH7 is
configured in C0584
6.6−11
See System
Manual
(extension)
C0122 OH4 limit 80 45 {1 °C} 85 Configuration of monitoring
OH4
l Monitoring of the heatsink
temperature
l Activating monitoring with
C0582
l Temperature in C0122
reached:
– Warning OH4 is initiated
See System
Manual
(extension)
C0125 Baudrate 0
0 9600 baud
LECOM baud rate
l Baud rate for accessory
module 2102
1 4800 baud
2 2400 baud
3 1200 baud
4 19200 baud
C0126 MONIT CE0 3
0 TRIP
Configuration of monitoring CE0
l Error message in case of
communication error AIF
See System
Manual
(extension)
2 Warning
3 Off
C0130 DIS: act Ti Active T
i
times for the speed
setpoint conditioning, function
block NSET
l Display of the additional
acceleration and deceleration
times for the main setpoint
(C0101, C0103)
l Activation via binary coding
of C0788/1 ... C0788/4
See System
Manual
(extension)
0 C12/C13
1 Tir1/Tif1
2 Tir2/Tif2
... ...
14 Tir14/Tif14
15 Tir15/Tif15
C0132
RFG fly delay May only be changed by Lenze
service personnel!
C0133
HLG fly delay May only be changed by Lenze
service personnel!
efesotomasyon.com - Lenze