Configuration
Code table
8
8.5
8.5−13
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0134 RFG charac 0
0 Linear linear characteristic
Ramp function generator
characteristic, function block
NSET
l Characteristic of the main
setpoint
See System
Manual
(extension)
1 S−shaped S−shaped
characteristic
C0135 Control word 0
Bit Assignment
Control word, function block AIF
l Decimal control word when
networked via automation
interface AIF
l 16−bit information, binary
coded
See System
Manual
(extension)
0 reserved
1 reserved
2 reserved
3 Quick stop
4 reserved
5 reserved
6 reserved
7 reserved
8 Operation inhibited
9 Controller inhibit
10 TRIP SET
11 Trip reset
12 reserved
13 reserved
14 reserved
15 reserved
C0136 Display of the control words in
C0135, AIF−IN and CAN−IN1
See System
Manual
(extension)
1 Ctrl wrd C135 Control word C0135
2 Ctrl wrd CAN Control word CAN
3 Ctrl wrd AIF Control word AIF
C0141 FCODE (setval) 0.00 −199.9 {0.01 } 199.99 Main setpoint, freely
configurable code (FCODE)
l Used as main setpoint in the
basic configurations
C0005 = xxx1
C0142 Start options May only be changed by Lenze
service personnel!
C0143 limit 2 kHz 0.0 0.0 {0.1 Hz} 20.0 Speed−dependent switching
threshold
l Threshold for automatic
switching frequency
reduction
l The controller changes
automatically to 2 kHz when
this value falls below the
threshold
8.2−25
8.2−40
C0144
OH switch 1
0 Switch off Switch−over is not
active
Temperature−dependent
switching frequency reduction
l If the heatsink temperature
set in C0122 is reached
(warning OH4), the controller
switches to 2 kHz
1 Switch on Switch−over is active
C0145
select ref May only be changed by Lenze
service personnel!
C0146 fly current May only be changed by Lenze
service personnel!
C0147 fly dt−f May only be changed by Lenze
service personnel!