Configuration
Code table
8
8.5
8.5−14
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0148
ident run 0
0 WRK
stop
Ready
Motor data identification
1. Inhibit controller, wait until
drive has stopped
2. Enter the correct values of
the motor nameplate into
C0087, C0088, C0089, C0090,
C0091
3. Set C0148 = 1, confirm with
"
4. Enable controller
The identification
– starts, goes off. The
motor "whistles" but does
not rotate!
– lasts approx. 1 ... 2 min
– is completed when is
lit again
5. Inhibit controller:
6.6−16
1 WRK
run
Start identification
C0149
Auto ident 0
0 Id
inactive
Automatic identification is
inactive
Automatic motor data
identification
1. Inhibit controller, wait until
drive has stopped
2. Enter the correct values of
the motor nameplate into
C0087, C0088, C0089, C0090,
C0091
3. Set C0149 = 1, confirm with
"
4. Enable controller
The identification
– starts, goes off. The
motor "whistles" but does
not rotate!
– lasts approx. 1 ... 2 min
– is completed when is
lit again
5. Inhibit controller:
6.6−16
1 Id
active
Automatic identification is
active
l The identification starts
automatically after
controller enable
l After a faulty identification,
the process is restarted
after TRIP RESET or mains
switching and subsequent
controller enable
C0150 Status word
Bit00 — Bit08 Status code
Read only
Decimal status word for
networking via automation
interface (AIF)
l Binary interpretation
indicates the bit states
See System
Manual
(extension)
Bit01 IMP Bit09 Status code
Bit02
— Bit10 Status code
Bit03
— Bit11 Status code
Bit04
— Bit12 Warning
Bit05
— Bit13 Message
Bit06
n = 0 Bit14 —
Bit07
CINH Bit15 —
C0151
DIS: FDO (DW) Read only
l Free digital outputs (FDO)
l Hexadecimal representation
of the digital output signals
configured in C0116
l Binary interpretation
indicates the bit states
See System
Manual
(extension)
efesotomasyon.com - Lenze