Configuration
Code table
8
8.5
8.5−37
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0595 MONIT CE4 3
0 TRIP
Configuration of monitoring
CE4, BUS−OFF (system bus)
See System
Manual
(extension)
2 Warning
3 Off
C0596 NMAX limit 4000 0 {1 rpm} 36000 Configuration of monitoring
N
max
, maximum system speed
exceeded
See System
Manual
(extension)
C0597 MONIT LP1 3
0 TRIP
Configuration of monitoring the
motor phases LP1
See System
Manual
(extension)
2 Warning
3 Off
C0598 MONIT SD5 3
0 TRIP
Configuration of monitoring
SD5, open circuit at analog input
X6/1, X6/2
See System
Manual
(extension)
2 Warning
3 Off
C0599 Limit LP1 5.0 1.0 {0.1 %} 10.0 Configuration of current limit
LP1, current limit value for
monitoring the motor phases in
C0597
See System
Manual
(extension)
C0600 Function 1
0 OUT = IN1
Function selection, function
block ARIT2
See System
Manual
(extension)
1 OUT = IN1 + IN2
2 OUT = IN1 − IN2
3 OUT = IN1 * IN2
4 OUT = IN1 / IN2
5 OUT = IN1 / (100 − IN2)
C0601
Selection list 1 Configuration of analog input
signal, function block ARIT2
1 CFG: IN 1000 FIXED0% ARIT2−IN1
2 CFG: IN 1000 FIXED0% ARIT2−IN2
C0602 −199.99 {0.01 %} 199.99 Function block ARIT2
l Display of the signals linked
in C0601
1 DIS: IN ARIT2−IN1
2 DIS: IN ARIT2−IN2
C0603 Function 1
0 OUT = IN1
Function selection, function
block ARIT3
See System
Manual
(extension)
1 OUT = IN1 + IN2
2 OUT = IN1 − IN2
3 OUT = IN1 * IN2
4 OUT = IN1 / IN2
5 OUT = IN1 / (100 − IN2)
C0604
Selection list 1 Configuration of analog input
signal, function block ARIT3
1 CFG: IN 1000 FIXED0% ARIT3−IN1
2 CFG: IN 1000 FIXED0% ARIT3−IN2
C0605 −199.99 {0.01 %} 199.99 Function block ARIT3
l Display of the signals linked
in C0604
1 DIS: IN ARIT3−IN1
2 DIS: IN ARIT3−IN2
C0608
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block SQRT1
See System
Manual
(extension)
C0609 DIS: IN −199.99 {0.01 %} 199.99 Function block SQRT1
l Display of the signal linked in
C0608
efesotomasyon.com - Lenze