Configuration
Code table
8
8.5
8.5−49
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0775
CFG: D 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FLIP2
See System
Manual
(extension)
C0776
CFG: CLK 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FLIP2
l Each LOW−HIGH edge at
FLIP2−CLK switches the signal
at FLIP2−D to FLIP2−OUT
C0777
CFG: CLR 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FLIP2
l Resets the flip−flop
l HIGH: sets FLIP2−OUT = LOW
l Input has highest priority
C0778 0 1
Function block FLIP2
l Display of the signals linked
in C0775, C0776 and C0777
1 DIS: D
2 DIS: CLK
3 DIS: CLR
C0780
CFG: N 5250 NLIM1−OUT Selection list 1 Configuration of analog input
signal, function block NSET
l Main setpoint
See System
Manual
(extension)
C0781
CFG: N−INV 10251 R/L/Q−R/L Selection list 2 Configuration of digital input
signal, function block NSET
l HIGH: main setpoint (C0780)
is inverted
C0782
CFG: NADD 55 AIN2−OUT Selection list 1 Configuration of analog input
signal, function block NSET
l Additional setpoint
C0783
CFG:
NADD−INV
1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NSET
l HIGH: additional setpoint
(C0783) is inverted
C0784
CFG:
CINH−VAL
5001 MCTRL−NACT Selection list 1 Configuration of analog input
signal, function block NSET
l The signal is accepted by the
main setpoint integrator
when the controller is
inhibited
C0785
CFG: SET 5000 MCTRL−nset2 Selection list 1 Configuration of analog input
signal, function block NSET
l When NSET−LOAD = HIGH,
the signal is accepted by the
main setpoint integrator
C0786
CFG: LOAD 5001 MCTRL−QSP−OUT Selection list 2 Configuration of digital input
signal, function block NSET
l HIGH: The signal at NSET−SET
is accepted by the mains
setpoint integrator
l Control of both ramp
function generators in special
situations, e.g. quick stop
efesotomasyon.com - Lenze