IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0787
Selection list 2 Configuration of digital input
signals, function block NSET
l Activation of a fixed speed
via binary coding of the
digital input signals
l For coding see description of
function block NSET
l Parameter setting of the
fixed speeds (JOG setpoints)
in C0039
See System
Manual
(extension)
1 CFG: JOG 53 DIGIN3 NSET−JOG*1
2 CFG: JOG 1000 FIXED0 NSET−JOG*2
3 CFG: JOG 1000 FIXED0 NSET−JOG*4
4 CFG: JOG 1000 FIXED0 NSET−JOG*8
C0788
Selection list 2 Configuration of digital input
signals, function block NSET
l Activation of additional
acceleration and deceleration
times for the mains setpoint
via binary coding of the
digital input signals
l For coding see description of
function block NSET
l Parameter setting of the
times in C0101 and 103
1 CFG: TI 1000 FIXED0 NSET−Ti*1
2 CFG: TI 1000 FIXED0 NSET−Ti*2
3 CFG: TI 1000 FIXED0 NSET−Ti*4
4 CFG: TI 1000 FIXED0 NSET−Ti*8
C0789
CFG: RFG−0 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NSET
l HIGH: Guides the main
setpoint integrator to 0 via
the current T
i
times
See System
Manual
(extension)
C0790
CFG:
RFG−STOP
1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NSET
l HIGH: Keeps the main
setpoint integrator on its
current value