Appendix
Index
14
14.2
14.2−2
EDSVF9383V EN 6.0−11/2009
Configuration, 8−1
− Analog input signals, 6.5−4
− Analog output signals, 6.5−6
− Analog outputs, 6.5−6
− changing the direction of rotation, 6.10−5
− Code table, 8.5−1
− Controller inhibit (DCTRL1−CINH), 6.4−1
− Current limits, 6.6−15
− Digital input signals, 6.5−1
− Digital output signals, 6.5−3
− Digital outputs, 6.5−3
− Display functions, 9.1−1
− Maximum field frequency, 6.10−1
− Minimum field frequency, 6.10−1
− Monitoring
Current load of controller (Ixt monitoring), 8.3−4
Heatsink temperature, 8.3−6
Monitoring times for process data input objects, 8.3−2
− monitoring, 8.3−1
bus off, 8.3−2
DC−bus voltage, 8.3−7
motor temperature, 8.3−5
reset node, 8.3−2
− monitoring functions
overview, 8.4−1
responses, 8.3−1
− motor data collection, 6.6−16
− Oscillation damping, 6.11−3
− Quick stop (QSP), 6.10−4
− Relay output, 6.5−3
− Slip compensation, 6.11−1
− switching frequency of inverter, 6.9−1
− Table of attributes, 8.7−1
− Umin boost, 6.8−6
Conformity, 1.2−1
Control cable, 5.2−3
Control cables, connection between master and
slave, 5.4−5
Control terminals, 5.5−1
− Changing the assignment of X5, 6.5−1
− Changing the assignment of X6, 6.5−1
Control word (AIF), 8.5−13
Controller
− application as directed, 1.2−1
− in clamp operation, 9.4−2
− labelling, 1.2−1
Controller inhibit, Drive behaviour, 6.4−1
Current limits, 6.6−15
Current load of controller, Ixt monitoring, 8.3−4
D
DC bus
− Cable cross−sections for the, 5.3−5 , 5.4−9
− Cable selection, 3.7−3
− connection to the, 5.3−5 , 5.4−9
− Fuses for the, 5.3−5 , 5.4−9
DC busbars, installation between master and slave, 5.4−4
DC injection braking (GSB)
− automatic, 8.2−35 , 8.2−57
− manual, 8.2−33 , 8.2−55
DC supply, 5.2−1
DC−bus cable, shielding, 5.3−5 , 5.4−9
DC−bus connection
− Distributed supply, 10.6−1
− Possible combinations, 10.2−1
DC−bus operation, 10−1
− Braking operation in, 10.7−1 , 12.4−1
− Conditions, 10.2−1
− Several drives, 10−1
DC−bus voltage, 8.2−27 , 8.2−42 , 8.3−7 , 8.5−6 , 9.1−1
− monitoring, 8.3−7
− overvoltage, 8.3−7
− Undervoltage, 8.3−7
Deceleration, 6.10−1
Deceleration time Tif, additional setpoint of NSET, 8.5−19
Definition of notes used, 1.4−1
Definitions, Terms, 14.1−1
Derating, 6.6−16 , 6.9−1 , 6.11−3 , 8.2−38 , 8.2−60
device control, 8.5−2
Device protection, 2.3−1
Diagnostics, 7.2−10 , 9.1−1 , 9.1−2
Diameter calculator (DCALC1), 8.2−1
Digital frequency input, connection to X9, 5.8−1
Digital frequency output, connection to X10, 5.8−1
Digital input signals, 6.5−1
Digital inputs, Terminal assignment, 5.5−9
Digital inputs/outputs, Terminal assignment, 11.3−2
Digital output signals, 6.5−3
Digital outputs
− Configuration, 6.5−3
− terminal assignment, 5.5−9
Dimensions, 3.1−2 , 4.2−1 , 4.3−1 , 12.2−2
Direction of rotation, inhibiting, 8.2−39 , 8.2−61