Project planning
Pr
ocedure of an inverter conguraon process
Dimensioning
3 methods for dimensioning
Fast: Selecon of the inverter based on the motor data of a 4-pole asynchronous motor.
Detailed: In order to opmise the selecon of the inverter and all drive components, it is
worth to execute the detailed system dimensioning based on the physical requirements of the
applicaon. For this purpose, Lenze provides the «Drive Soluon Designer» (DSD) design pro-
gram.
Manual: The following chapter guides you step by step to the selecon of a drive system.
Workow of a conguraon process
Dene required input variable
Calculate range of adjustment and determine rated point
Determine motor based on the rated data
Dene
correcon factors for the inverter
Determine inverter based on the rated data
Check motor/inverter combinaon
Determine brake resistance
Final conguraon
Dene required input variables
Operang mode S1 or S6
Max. load torque M
L
,max
Nm
Max. load speed n
L,max
rpm
Min. load speed n
L,min
rpm
Site altude H m
Temperature in the control cabinet T
U
°C
Calculate range of adjustment and determine rated point
Calculaon
Seng range
Project planning
Pr
ocedure of an inverter conguraon process
Dimensioning
10