Inverter overview
Comparison of i500
Inverter i510 i550
Applicaon area Pumps and fans, conveyor, travelling, winding, forming, tool and hoist drives
Electrical supply sys-
t
em
1/N/PE 1/3/PE 3/PE 1/N/PE 1/3/PE 3/PE 3/PE
AC 170 ... 264 V AC 170 ... 264 V AC 340 ... 528 V AC 170 ... 264 V AC 170 ... 264 V AC 170 ... 264 V AC 340 ... 528 V
45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz 45 ... 65 Hz
Motor power 0.25 ... 2.2 kW 0.25 ... 2.2 kW 0.37 ... 2.2 kW 0.25 ... 2.2 kW 0.25 ... 2.2 kW 4.0 ... 5.5 kW 0.37 ... 75 kW
Inverter output cur-
rent
1.7 ... 9.6 A 1.7 ... 9.6 A 1.3 ... 5.6 A 1.7 ... 9.6 A 1.7 ... 9.6 A 16.5 ... 23 A 1.3 ... 150 A
Inverter eciency
class
IE2 according to EN 50598-2
Max. inverter output
current
150 % at an overload me of 60 s
200 % at an overload me of 3 s
RFI lters Integrated not integrated Integrated Integrated not integrated Integrated Integrated
Dissipaon of regen-
erave energy
- - - Brake resistor Brake resistor Brake resistor Brake resistor
DC-bus connec-
on
Inverter version Control cabinet
Degree of protecon IP20 according to EN 60529
Inverter mounng
type
Installaon, easy mounng via keyhole suspension
Control connecons
and networks
Basic I/Os Standard-I/O
5 digital inputs - 1 digital output 5 digital inputs - 1 digital output
2 analog inputs - 1 analog output 2 analog inputs - 1 analog output
HTL incremental encoder via 2 digital inputs
Modbus or CANopen (switchable) Modbus
CANopen
EtherCAT
EtherNet/IP
PROFIBUS
PROFINET
Applicaon I/O
7 digital inputs - 2 digital outputs
2 analog inputs - 2 analog outputs
HTL incremental encoder via 2 digital inputs
More connecons Relay Relay
Connecon for PTC or thermal contact
External 24 V supply
Funconal safety Without STO (Safe torque o)
Approvals CE, RoHS2, UL (for USA and Canada), EAC
Interference suppres-
sion
Residenal areas C1, industrial premises C2
About Lenze
In
verter overview
6