EasyManua.ls Logo

Lenze i550 - Quick Commissioning via Terminal Control

Lenze i550
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Features
Mot
or seng range
Rated point 120 Hz
Only possible with Lenze MF motors.
The rated motor torque is available up to 120 Hz.
Compared to the 50-Hz operaon, the seng range increases by 2.5 mes.
It is quite simply not possible for a drive to be operated any more eciently in a machine.
V/f at 120 Hz
120 Hz f
M, U
M
N
U
AC
V Voltage U
A
C
Mains voltage
M Torque M
rated
Rated torque
f Frequency
Rated point 87 Hz
The rated motor torque is available up to 87 Hz.
Compared to the 50-Hz operaon, the seng range increases by 1.74 mes.
For this purpose, a motor with 230/400 V in star connecon is driven by a 400-V inverter.
The inverter must be dimensioned for a rated motor current of 230 V.
V/f at 87 Hz
f
M, U
M
N
U
AC
f
N
Product
informaon
Features
Motor seng range
32