Technical data
St
andards and operang condions
Conformies/approvals
Conformies
CE 2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC TR TC 004/2011 Eurasian conformity: safety of low voltage equipment
TP TC 020/2011 Eurasian conformity: electromagnec compability of technical
means
RoHS 2 2011/65/EU Restricons for the use of specic hazardous materials in electric
and electronic devices
Approvals
UL UL 61800-5-1 for USA and Canada (requirements of the CSA 22.2 No. 274)
0.25 kW … 45 kW (55 kW … 75 kW in preparaon)
Protecon of persons and device
protecon
Degree of protecon
IP20 EN 60529
Type 1 NEMA 250 Protecon against contact
Open type only in UL-approved systems
Insulaon resistance
Overvoltage category III EN 61800-5-1 0 … 2000 m a.m.s.l.
Overvoltage category II above 2000 m a.m.s.l.
Control circuit isolaon
Safe mains isolaon by double/reinforced insu-
laon
EN 61800-5-1
Protecve measures against
Short circuit
earth fault Earth fault strength depends on the operang status
overvoltage
Motor stalling
Motor overtemperature PTC or thermal contact, I²xt monitoring
Leakage current
> 3.5 mA AC, > 10 mA DC EN 61800-5-1 Observe regulaons and safety instrucons!
Cyclic mains switching
3 mes per minute Without restricons
Starng current
≤ 3 x rated mains current