1/3-phase mains connecon 230/240 V
Connecon plan
The wiring diagram is valid for I5xAExxxD
inverters.
X266
X267
EtherNet/IP
X256
X257
PROFINET
IN
OUT
X246
X247
EtherCAT
IN
OUT
X226
PROFIBUS
TB
COM
TA
X216
Modbus
CL
CG
CH
X216
CANopen
Safety STO
X1
SIA
GS
SIB
DC 24 V SELV/PELV
(+19.2 … +28.8 V)
"
1k ... 10k
0 ... 10 V
S1
DI3 DI4
100 mA
4.4k
+24 V +10 V
4.4k
4.4k
4.4k
4.4k
10 mA
Standard I/O
GND
DO1
DI1
DI2
DI3
DI4
DI5
24E
GND
AI1
AI2
10V
GND
AO1
24V
24E
X3
24V
4.4k
DI7
4.4k
AO2
DI1
DO2
GND
GND
DI6
Application I/O
X105
U
V
W
Rb1
Rb2
+
X109
T1
T2
""
M
3~
+
J
J
NC
NO
COM
X9
AC 240 V
3 A
F1
F3
Q1
X100
L1
L2/N
3/PE
AC 170 V ... 264 V
45 Hz ... 65 Hz
L3
+
2/PE
AC 170 V ... 264 V
45 Hz ... 65 Hz
+
F1
F2
Q1
X100
L1
L2/N
L3
X100
L1
L2/N
L3
F1
Q1
PE
N
L3
L2
L1
3/N/PE
AC 208 V ... 240 V
PE
N
L3
L2
L1
+
1/N/PE
AC 170 V ... 264 V
45 Hz ... 65 Hz
3/N/PE
AC 400 V
Fig. 4: Wiring example
S1 Start/Stop
Fx
Fuses
Q1 Mains contactor
--- Dashed line = opons
Mounng/
installaon
Electrical installaon
Mains connecon