Inverter i550-C1.1/230-2 i550-C1.5/230-2 i550-C2.2/230-2
Rated power kW 1.1 1.5 2.2
Mains voltage range 1/N/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Rated mains current
without mains choke A 14.3 16.7 22.5
with mains choke A 11.9 13.9 16.9
Mains voltage range 3/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Rated mains current
without mains choke A 7.8 9.5 13.6
with mains choke A 5.6 6.8 9.8
Apparent output power kVA 2.2 2.6 3.6
Output current
2 kHz A 6 7 9.6
4 kHz A 6 7 9.6
8 kHz A 6 7 9.6
16 kHz A 4 4.7 6.4
Power loss
4 kHz W 37 43 60
8 kHz W 42 50 70
at controller inhibit W 6 6 6
Overcurrent cycle 180 s
Max. output current A 9 10.5 14.4
Overload me s 60 60 60
Recovery me s 120 120 120
Max. output current during the
r
ecovery me
A
4.5 5.3 7.2
Overcurrent cycle 15 s
Max. output current A 12 14 19.2
Overload me s 3 3 3
Recovery me s 12 12 12
Max. output current during the
r
ecovery me
A
4.5 5.3 7.2
Brake chopper
Max. output current A 12 12 12
Min. brake resistance Ω 33 33 33
Max. motor cable length shielded
without EMC category m 50
Weight kg 1.35
Technical data
1/3-phase mains connecon 230/240 V
Ra
ted data
44

Table of Contents