Single−axis controllers
Wiring
Device 292 A (150 kW)
3
138
EDS94SPP101 EN 10.2
Motor temperature monitoring
Terminal X106 Labelling Description
T1 T2
T1
T2
Motor temperature monitoring with PTC element (type−A sensor,
switching performance according to EN 60947−8 for type−A tripping units)
or thermostat (NC contact).
SSP94KL0X8
Shield connection
Terminal data
Max. conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
flexible
2.5
12 0.5 ... 0.6 4.5 ... 5.3
Slot
0.6 x 3.5
with wire end ferrule
Motor brake control (optional)
Note!
The motor holding brake cannot be released without mains or DC−bus voltage.
Terminal X107 Labelling Description
Connection of the motor holding brake
BD1
BD2
+ (Lenze: WH)
− (Lenze: BN)
E94AZHx0101: 24 V DC, max. 5.0 A
Observe correct polarity!
+ / −
Supply voltage for the motor holding brake (18 ... 30 V DC)
Observe correct polarity!
SSP94X6107
Terminal data
Max. conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
flexible
2.5
12 0.5 ... 0.6 4.5 ... 5.3
Slot
0.6 x 3.5
with wire end ferrule
Stripping length or contact length: 8 mm