Single−axis controllers
Control terminals
3
155
EDS94SPP101 EN 10.2
Digital outputs
The controller features four freely configurable digital outputs.
Electrical data
24O
GO
24 V external voltage source, optional
according to IEC 61131−2
SELV/PELV
Current consumption Max. 300 mA
DO1
...
DO4
GO
Switching level according to IEC 61131−2
LOW 0 V ... +5 V
HIGH +15 V ... +30 V
Output current Max. 50 mA
Load > 480 at 24 V
Note!
For stable digital output states, in particular during the starting phase of the
controller, you must use an external 24V supply for the digital outputs.
Note!
Digital inputs and digital outputs have separated reference potentials (GI and
GO). If you interconnect inputs and outputs, the reference potentials are
connected as well by an external bridge.
24 V =
~
+
-
F
1
GND
In
0
DO4
DO3
DO2
DO1
24O
GO
X4
DO4
DO3
DO2
DO1
24O
GO
X4
SSP94X4DO1
Fig. 3−33 Wiring principle
Wiring with a digital input, e.g. a PLC
Digital control (relay, valve, ...) with an external 24−V supply
X4 Terminal for the digital outputs
In Digital input, e.g. of a control
GND Earth reference potential
F Fuse