Regenerative power supply modules
Wiring
Earthing of internal EMC filters
6
322
EDS94SPP101 EN 10.2
The measure for the mains filter of the power supply/regenerative feedback modules
(only in the case of operation in the IT system)
Carry out the measure before installation and wiring.
How to proceed:
ƒ Undo 8 fixing screws of the housing cover
ƒ Remove housing cover
ƒ Unscrew and remove IT screw with spring washer
ƒ Screw in IT screw with spring washer at the parking position
ƒ Fit housing cover
ƒ Screw in and tighten 8 fixing screws of the housing cover
E94AZMR010