Accessories (overview)
Function modules
Digital frequency
8
414
EDS94SPP101 EN 10.2
Rated data
Logic level [V]
Inputs Outputs
low high low high
TTL 5 V (standard) 0 ... 0.8 2.0 ... 5.0 0 ... 0.4 2.4 ... 5.0
Functions on X9
ƒ Input for encoder signals with TTL level
ƒ Voltage supply +5 V for encoder
ƒ Sensor lead (sense) at regulated voltage supply (Lenze setting)
max. control range of the voltage drop on the cable: 4 V (corresponds to 5 ... 9 V
output voltage on X9/4)
ƒ Digital input signal (only with regard to unused or external voltage supply)
Functions on X10
ƒ Output for encoder signals with TTL level, directly or simulated
ƒ Voltage supply +5 V
ƒ Digital output signal