Accessories (overview)
Function modules
Digital frequency
8
415
EDS94SPP101 EN 10.2
Assignment of the Sub−D plug connector
Stop!
The output voltages on X9/4 and on X10/4 may only be charged at a total of
max. 150 mA.
If the output voltage on X9/4 is used, no digital input signal may be applied to
X9/8. In this case, the cable serves as a sensor lead. In case of a connection
error, the components connected to X9 are damaged.
Stop!
The output voltages on X9/4 and on X10/4 may not be interconnected. This
applies to both the wiring of several modules and to the wiring of one module
(e. g. for purposes of simulation).
Use system cables not connecting pin 4 for this applications only.
Tip!
We recommend the use of Lenze system cables. For this purpose, please read
the documentation for the basic device.
X9 Pin Designation Explanation
1
6
5
9
1 B
TTL input signal by encoder or encoder simulation
2 A
3 A
4 +5 V Regulated voltage supply for encoder
(pin 8 = sense must be used, max. control range 5 ... 9 V)
5 GND
6 Z
TTL input signal by encoder or encoder simulation
7 Z
8
The function of this cable has to be set in the basic device:
S
Lc
E
Sense (sensor lead for voltage regulation, Lenze setting)
Lamp control
Enable
SUBD09010
9 B TTL input signal by encoder or encoder simulation
X10 Pin Designation Explanation
16
59
1 B
TTL output signal from the encoder or encoder simulation
Maximum output current: 20 mA per channel
2 A
3 A
4 +5 V V
CC
±6 %
5 GND
6 Z
TTL output signal from the encoder or encoder simulation
Maximum output current: 20 mA per channel
7 Z
8 Enable Digital output signal
SUBD09010
9 B TTL output signal from the encoder or encoder simulation
Maximum output current: 20 mA per channel