EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories (overview)
Motor holding brake control modules
Overview
8
446
EDS94SPP101 EN 10.2
Monitoring functions
Motor brake control module
Brake status Module−internal monitoring No monitoring
Brake is not controlled
(brake is applied)
Supply voltage of brake
not available
not connected correctly
Supply voltage
too high
too low
e.g. 18 V instead of 24 V
Brake current
too high
too low
Brake cable not connected
correctly
Brake is controlled
(brake is released)
Short circuits
cable "+" or "−"
cable "BD1" or "BD2"
Open circuit
cable "+" or "−"
cable "BD1" or "BD2"
ƒ Single Drive E94xS... devices: Monitoring active from V
DC
bus
> 250 V
ƒ Multi Drive E94AM... devices: Monitoring active independent of V
DC
bus
V
DC
bus
= DC−bus voltage
ƒ Errors can be evaluated under code C02609/8.
The externally controllable E94AZHN002x modules can be monitored via the digital
output (recommended).
Digital output DO
Status Description
HIGH No faults
LOW Fault
Supply voltage for motor holding brake is missing
Motor holding brake not connected to power supply
Brake cable defective
Open circuit
Short circuit
Supply voltage for motor brake control is missing
Note!
The supply status can be reported to the standard device via the error channel.
For more information, please see the software manual or the online help (see
description of C02609/8).
Operating conditions
The operating conditions correspond to the operating conditions for the standard device
to which the DC−feeding point is connected.

Table of Contents

Other manuals for Lenze L-force 9400

Related product manuals