Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHY0025
8
480
EDS94SPP101 EN 10.2
Standards
Conformity and approval
Conformity
CE
2014/35/EU Low−Voltage Directive
CE 2014/30/EU EMC Directive
EAC TP TC 004/2011
(TR CU 004/2011)
On safety of low voltage
equipment
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
EAC TP TC 020/2011
(TR CU 020/2011)
Electromagnetic
compatibility of technical
means
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
Approval
C
UR
US
UL61800−5−1 Power Conversion Equipment
(File No. E132659) for USA
CSA C22.2 No. 274−13 Power Conversion Equipment
(File No. E132659) for Canada
General electrical data
EMC
Noise emission EN 61800−3 Conducted, category C2.
Noise immunity EN 61800−3
Burst on mains cable: 2 kV/5 kHz
Burst on control cable: 2 kV/5 kHz
Surge on mains cable:
1 kV (1.2 s/50 s;
phase − phase)
2 kV (1.2 s/50 s; phase − PE)
Rated data
Voltage Frequency Rated current [A]
Number of
phases
[V] [Hz] up to +45 °C up to +55 °C
E94AZHY0025 230/290 50/60 0.75/0.75 0.54/0.54 1
E94AZHY0025 205/260 0 (DC) 0.75/0.75 0.54/0.54 1
Temperature in the control cabinet
Area Values
Input voltage AC 230 V (180 ... 317 V), 45 ... 65 Hz
Output voltage DC 205 V With mains voltage of AC 230 V
Brake current 0.1 ... 0.75 A
Cable protection Recommendation: 5 A, tripping characteristic "B" or "C"
Control input
Control voltage
Internal
Control current
Protective function
Max. connectable cable
cross−section
2.5 mm
2
AWG 12
Maximum cable length 150 m