Motor holding brake control modules
Motor holding brake control module E94AZHY0025
8
481
EDS94SPP101 EN 10.2
Permissible operating frequencies
Recommended brake Power Coil: Voltage DC 205 V Permissible operating frequency
Type P [W] L [H] I [A] (20 °C) [1/min]
BFK457−06E
BFK458−06E
20
76 0.10 60
BFK457−08E
BFK458−08E
25 66 0.12 60
BFK457−10E
BFK458−10E
30 85 0.15 60
BFK457−12E
BFK458−12E
40 107 0.20 40
BFK457−14E
BFK458−14E
50 102 0.24 30
BFK457−16E
BFK458−16E
55 127 0.27 20
BFK457−18E
BFK458−18E
85 100 0.41 10
BFK457−20E
BFK458−20E
100 115 0.49 8
BFK457−25E
BFK458−25E
110 134 0.54 6
Installation steps
E94AZHY003
1. Plug the motor brake control module onto the terminals of the standard device.
Ensure that both clips snap into the slots of the standard device!
2. Check that the motor brake control module is securely connected.