Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHY0025
8
481
EDS94SPP101 EN 10.2
Permissible operating frequencies
Recommended brake Power Coil: Voltage DC 205 V Permissible operating frequency
Type P [W] L [H] I [A] (20 °C) [1/min]
BFK457−06E
BFK458−06E
20
76 0.10 60
BFK457−08E
BFK458−08E
25 66 0.12 60
BFK457−10E
BFK458−10E
30 85 0.15 60
BFK457−12E
BFK458−12E
40 107 0.20 40
BFK457−14E
BFK458−14E
50 102 0.24 30
BFK457−16E
BFK458−16E
55 127 0.27 20
BFK457−18E
BFK458−18E
85 100 0.41 10
BFK457−20E
BFK458−20E
100 115 0.49 8
BFK457−25E
BFK458−25E
110 134 0.54 6
Installation steps
E94AZHY003
1. Plug the motor brake control module onto the terminals of the standard device.
– Ensure that both clips snap into the slots of the standard device!
2. Check that the motor brake control module is securely connected.