EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHN0026
8
498
EDS94SPP101 EN 10.2
Rated data
Voltage Frequency Rated current [A]
Number of
phases
[V] [Hz] up to +45 °C up to +55 °C
E94AZHN0026 400/480 50/60 0.75/0.75 0.61/0.61 1
E94AZHN0026 180/216 0 (DC) 0.75/0.75 0.61/0.61 1
Temperature in the control cabinet
Field Values
Input voltage AC 400 V (320 ... 528 V), 45 ... 65 Hz
Output voltage DC 180 V at a mains voltage of AC 400 V
Brake current 0.1 ... 0.61 A
Cable protection Recommendation: 5 A, tripping characteristic "B" or "C"
Control input DI
Signalling output DO
Control voltage
DC 24 V, PLC level
HIGH
LOW
DC +15 ... 30 V
DC 0 ... +3 V
Control current
Input 5 ... 10 mA
Output 5 ... 50 mA
Protective function Protected against polarity reversal up to DC 60 V
Max. connectable cable
cross−section
2.5 mm
2
AWG 12
Maximum cable length 150 m
Permissible operating frequencies
Recommended brake Power Coil: Voltage DC 180 V Permissible operating frequency
Type P [W] L [H] I [A] (20 °C) [rpm]
BFK457−06E
BFK458−06E
20
60 0.11 60
BFK457−08E
BFK458−08E
25 50 0.14 60
BFK457−10E
BFK458−10E
30 69 0.17 60
BFK457−12E
BFK458−12E
40 81 0.22 40
BFK457−14E
BFK458−14E
50 78 0.28 30
BFK457−16E
BFK458−16E
55 102 0.31 20
BFK457−18E
BFK458−18E
85 77 0.47 10
BFK457−20E
BFK458−20E
100 92 0.56 8
BFK457−25E
BFK458−25E
110 102 0.61 6