EasyManua.ls Logo

Lenze L-force 9400

Lenze L-force 9400
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories (overview)
Filters
Mains filters for power supply modules E94AZMPxxxx (8 ... 29 A)
8
548
EDS94SPP101 EN 10.2
Electrical installation
Standard mounting Mounting variant
L1
1 (BK)
2 (BK)
3 (BK)
PE (GN/YE)
L1
L1
L2 L2
L2
L3 L3
L3
+
+
+
L3
PE
L1
L2
F1...F3
X301 X111
X112
X302
E94AZPxxxxx
K1
T1 T2
E94AZMPxxxx
L1
1 (BK)
2 (BK)
3 (BK)
PE (GN/YE)
L1
L1
L2
L2
L2
L3
L3
L3
+
+
+
L3
PE
L1
L2
F1...F3
X301
X111
X112
X302
E94AZPxxxxx
K1
T1 T2
E94AZMPxxxx
SSP94NF105 SSP94NF105
Fig. 8−4 Connection concept
E94AZMPxxxx Mains filter
E94AZPxxxxx Installation backplane for 9400 DC power supply module
F1 ... F3 Fuses
K1 Mains contactor
Mains
Terminal X301 Labelling Description
L1
L2
L3
Connection of the mains phases L1, L2, L3
Connection for the supply−side PE conductor with M5 ring cable lug
SSP94NF106
Terminal data
Max. conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
E94AZxP0084
10
6 1.2 ... 1.5 10.6 ... 13.3 PH1
E94AZxP0294
PE connection data
Æ Starting torque
[mm] [Nm] [lb−in]
E94AZxP0084
M5
3 26.5 SW 8
E94AZxP0294

Table of Contents

Other manuals for Lenze L-force 9400